This study investigates fluid absorption behavior of an unirradiated and a heavily crosslinked ultra-high molecular weight polyethylene (UHMWPE) exposed to bovine serum with pressures varying from 0.1 to 10 MPa. The time-response of serum absorption is biphasic, with an initial “soak-in” phase (<1 week) of rapidly increasing mass before settling to a steady-state phase of mass increasing more gradually and linearly with time. Initial soak-in absorption of the unirradiated and crosslinked UHMWPE are very similar, increasing from 0.8 to 4.3 g/m2 as serum pressure is increased from 0.1 to 10 MPa. Steady-state absorption rates of the unirradiated UHMWPE increase from 0.8 to 1.5 (mg/m2)/hr as serum pressure is increased from 0.1 to 10 MPa, while absorption rates for the crosslinked UHMWPE are lower, increasing from approximately 0.28 to 0.85 (mg/m2)/hr over the same pressure range. Steady-state rate of absorption is also found to depend on temperature, with values at room temperature being two-fold less than at 37°C. Such fluid absorption characterization is critical to hip and knee simulator testing, in order to separate wear loss and serum absorption gain contributions to total mass change measurements of UHMWPE bearings. In addition to its pertinence in quantification of UHMWPE wear, the extent of fluid film lubrication in total joint replacements as implied by reported serum absorption behavior is also discussed.

1.
Muratoglu, O. K., Bragdon, C. R., O’Connor, D. O., Merrill, E. W., Jasty, M., and Harris, W. H., 1997, “Electron Beam Cross-Linking of UHMWPE at Room Temperature, A Candidate Bearing Material for Total Hip Arthroplasty,” World Tribology Congress Abstracts, p. 248.
2.
McKellop
,
H.
,
Shen
,
F. W.
,
Lu
,
B.
,
Campbell
,
P.
, and
Salovey
,
R.
,
1999
, “
Development of an Extremely Wear-Resistant Ultra High Molecular Weight Polyethylene for Total Hip Replacements
,”
J. Orthop. Res.
,
17
, p.
157
157
.
3.
Bragdon, C. R., O’Connor, D. O., Weinberg, E. A., Skehan, H. C., Muratoglu, O. K., Lowenstein, J. D., and Harris, W. H., 1999, “The Effect of Cycle Rate on the Wear of Conventional and Highly Crosslinked UHMWPE Acetabular Components using the Boston AMTI Hip Simulator,” Proceedings of the 45th Annual Meeting of the Orthopaedic Research Society, p. 831.
4.
McKellop, H., Shen, F. W., and Salovey, R., 1998, “Extremely Low Wear of Gamma-Crosslinked/Remelted UHMW Polyethylene Acetabular Cups,” Proceedings of the 44th Annual Meeting of the Orthopaedic Research Society, p. 17.
5.
Yao, J. O., Laurent M. P., and Gilbertson, J. N., 2000, “The Effect of the Minimum Load on the Fluid Uptake of UHMWPE Acetabular Liners,” Proceedings of the 46th Annual Meeting of the Orthopaedic Research Society, p. 568.
6.
Clarke
,
I. C.
,
Starkebaum
,
W.
,
Hosseinian
,
A.
,
McGuire
,
P.
,
Okuda
,
R.
,
Salovey
,
R.
, and
Young
,
R.
,
1985
, “
Fluid-Sorption Phenomena in Sterilized Polyethylene Acetabular Prostheses
,”
Biomaterials
,
6
, p.
184
184
.
7.
Bragdon, C. R., O’Connor, D. O., Weinberg, E. A., Skehan H. C., Muratoglu, O. K., Lowenstein, J. D., and Harris, W. H., 1999, “The Effect of Load Plus Motion versus Load Alone on Fluid Imbibition into UHMWPE,” Proceedings of the 25th Annual Meeting of the Society for Biomaterials, p. 176.
8.
Klapperich, C., Niedzwiecki, S., Pruitt, S., and Ries, M., 1999, “Surface Area and Sterilization Method Affect Fluid Sorption of Medical Grade UHMWPE: Implications for Simulator Studies,” Proceedings of the 45th Annual Meeting of the Orthopaedic Research Society, p. 828.
9.
Klapperich
,
C.
,
Niedzwiecki
,
S.
,
Ries
,
M.
, and
Pruitt
,
S.
,
2000
, “
Fluid Sorption of Orthopedic Grade Ultrahigh Molecular Weight Polyethylene in a Serum Environment is Affected by the Surface Area and Sterilization Method
,”
J. Biomed. Mater. Res.
,
49
, p.
73
73
.
10.
Bragdon, C. R., Muratoglu, O. K., O’Connor, D. O., Skehan, H., Jasty, M., and Harris, W. H., 2000, “New Insights into Fluid Imbibition into Highly Crosslinked Polyethylene Acetabular Components,” Proceedings of the 46th Annual Meeting of the Orthopaedic Research Society, p. 546.
11.
Muratoglu, O. K., Bragdon, C. R., O’Connor, D. O., Jasty, M., and Harris, W. H., 1999, “A Novel Method of Crosslinking UHMWPE to Improve Wear with Little or No Sacrifice on Mechanical Properties,” Proceedings of the 45th Annual Meeting of the Orthopaedic Research Society, p. 829.
12.
Meyer
,
D.
, and
Tichy
,
J.
,
1999
, “
Lubrication Model of an Artificial Hip Joint: Pressure Profile versus Inclination Angle of the Acetabular Cup
,”
ASME J. Tribol.
,
121
, p.
492
492
.
13.
Muratoglu, O. K., Bragdon, C. R., O’Connor, D. O., Skehan, H., Delaney, J., Jasty, M., and Harris, W. H., 2000, “The Comparison of the Wear Behavior of Four Different Types of Crosslinked Acetabular Components,” Proceedings of the 46th Annual Meeting of the Orthopaedic Research Society, p. 566.
You do not currently have access to this content.