Abstract
Within the study of fluid-elastic instability in heat exchangers tube banks, a considerable theoretical and experimental effort has been produced for understanding fluid–structure coupling in two-phase flow. This communication discusses the commonly accepted added mass modeling and proposes some ways of further improvement. Notably, it turns out that added mass may be overestimated in a two-phase flow. Taking into account this phenomenon improves the collapsing of flow-induced forces data.
Issue Section:
Technical Briefs
References
1.
Tanaka
,
H.
, and
Takahara
,
S.
, 1981
, “
Fluid Elastic Vibration of Tube Array in Cross Flow
,” J. Sound Vib.
,
77
(1
), pp. 19
–37
.10.1016/S0022-460X(81)80005-32.
Chen
,
S. S.
, and
Srikantiah
,
G. S.
, 2001
, “
Motion-Dependent Fluid Force Coefficients for Tube Arrays in Crossflow
,” ASME J. Pressure Vessel Technol.
,
123
(4
), pp. 429
–436
.10.1115/1.14010223.
Sawadogo
,
T.
, and
Mureithi
,
N. W.
, 2014
, “
Fluidelastic Instability Study in a Rotated Triangular Tube Array Subject to Two-Phase Cross-Flow. Part I: Fluid Force Measurements and Time Delay Extraction
,” J. Fluids Struct.
,
49
, pp. 1
–15
.10.1016/j.jfluidstructs.2014.02.0044.
Piteau
,
P.
,
Delaune
,
X.
,
Borsoi
,
L.
, and
Antunes
,
J.
, “
Experimental Identification of Fluid-Elastic Coupling Forces on a Square Tube Bundle Subjected to Single-Phase Cross-Flow
,” ASME
Paper No. PVP2016-63921.10.1115/PVP2016-639215.
Nishida
,
S.
,
Azuma
,
S.
,
Morita
,
H.
,
Hirota
,
K.
,
Kawakami
,
R.
, and
Nishikawa
,
Y.
, 2018
, “
Evaluation Method for in-Plane FEI of Triangular Array Tube Bundle
,” Ninth International Symposium on Fluid-Structure Interactions, Flow-Sound Interactions, Flow-Induced Vibration & Noise
, Toronto, ON, July 8–11, Paper No. FIV2018-149
.http://www.fiv2018.com/ocs/index.php/fiv2018/fivcan/paper/viewFile/149/1366.
Deri
,
E.
, 2018
, “
Operational Modal Analysis of a Triangular-Pitch Bundle Subjected to Two-Phase Cross-Flow
,” ASME J. Pressure Vessel Technol.
,
140
(3
), p. 031301
.10.1115/1.40387257.
Moran
,
J. E.
, and
Weaver
,
D. S.
, 2013
, “
On the Damping in Tube Arrays Subjected to Two-Phase Cross-Flow
,” ASME J. Pressure Vessel Technol.
,
135
(3
), p. 030906
.10.1115/1.40234218.
Delenne
,
B.
,
Gay
,
N.
,
Campistron
,
R.
, and
Banner
,
D.
, 1997
, “
Experimental Determination of Motion-Dependent Fluid Forces in Two-Phase Water-Freon Cross Flow
,” ASME
Paper No. IMECE1997-0129.10.1115/IMECE1997-01299.
Deri
,
E.
,
Nibas
,
J.
,
Ries
,
O.
, and
Adobes
,
A.
, 2015
, “
Measurement of Flow-Induced Forces: A Single Flexible Tube in a Rigid Triangular-Pitch Bundle Subjected to Two-Phase Cross-Flow
,” ASME
Paper No. PVP2015-45081.10.1115/PVP2015-4508110.
Pettigrew
,
M. J.
,
Taylor
,
C. E.
, and
Kim
,
B. S.
, 1989
, “
Vibration of Tube Bundles in Two-Phase Cross-Flow: Part 1—Hydrodynamic Mass and Damping
,” ASME J. Pressure Vessel Technol.
,
111
(4
), pp. 466
–477
.10.1115/1.326570511.
Chexal
,
B.
,
Merilo
,
M.
,
Maulbetsch
,
J.
,
Horowitz
,
J.
,
Harrison
,
J.
,
Westacott
,
J.
,
Peterson
,
C.
,
Kastner
,
W.
, and
Schmidt
,
H.
, 1997
, “
Void Fraction Technology for Design and Analysis
,” Electric Power Research Institute, Palo Alto, CA, Report No. TR-106326
.https://www.epri.com/research/products/TR-10632612.
Whalley
,
P. B.
, 1990
, Boiling, Condensation, and Gas-Liquid Flow
,
Oxford University Press
, Oxford, UK.13.
Fritz, R. J., 1972, “The Effect of Liquids on the Dynamic Motions of Immersed Solids,”
ASME J. Eng. Ind.
, 94(1), pp. 167–173.10.1115/1.3428107Copyright © 2022 by ASME
You do not currently have access to this content.