General components such as pressure vessels, piping, storage tanks, and so on are designed in accordance with the construction codes based on the assumption that there are no flaws in such components. There are, however, numerous instances in which in-service single or multiple volumetric flaws such as local thin areas are found in the equipment concerned. Therefore, it is necessary to establish a fitness for service rule, which is capable of evaluating these flaws. The procedure for a single flaw or multiple flaws has recently been proposed for assessing the flaws in the p-M (pressure-moment) diagram, which is an easy way to visualize the status of the component with flaws simultaneously subjected to internal pressure p and external bending moment M due to earthquake, etc. If the assessment point (Mr,pr) lies inside the p-M line, the component with flaws is judged to be safe. In this paper, numerous experiments and finite element analysis for a cylinder with external multiple volumetric flaws were conducted under (1) pure internal pressure, (2) pure external bending moment, and (3) subjected simultaneously to both internal pressure and external bending moment, in order to determine the plastic collapse load at volumetric flaws by applying the twice-elastic slope (TES) as recommended by ASME. It has been clarified that the collapse (TES) loads are much the same as those calculated under the proposed p-M line based on the measured yield stress.

1.
ASME
, 2004, Boiler and Pressure Vessel Code, Document IWA-3300, American Society of Mechanical Engineers, Philadelphia, PA.
2.
2005, “
Guide on Methods for Assessing the Acceptability of Flaws in Metallic Structures
,” British Standards Institution, BS7910.
3.
2007, “
Fitness For Service
,” American Society of Mechanical Engineers, API 579-1/ASME FFS-1.
4.
2007, FITNET FFS Procedure, Prepared by European Fitness for Service Thematic Network, Contract No. GIRT-CT-2001-05071, European Framework.
5.
Konosu
,
S.
, 2009, “
Assessment Procedure for Multiple Crack-Like Flaws in Failure Assessment Diagram (FAD)
,”
ASME J. Pressure Vessel Technol.
0094-9930,
131
, p.
041402
.
6.
Konosu
,
S.
, 2009, “
Assessment Procedure for Multiple Volumetric Flaws in p-M Diagram
,”
ASME J. Pressure Vessel Technol.
0094-9930,
131
, p.
031407
.
7.
Konosu
,
S.
, and
Mukaimachi
,
N.
, 2008, “
Plastic Collapse Assessment Procedure for Vessel With Local Thin Area Simultaneously Subjected to Internal Pressure and External Bending Moment
,”
ASME J. Pressure Vessel Technol.
0094-9930,
130
, p.
011207
.
8.
Konosu
,
S.
,
Kano
,
M.
,
Mukaimachi
,
N.
,
Komura
,
H.
, and
Takada
,
H.
, 2009, “
Plastic Collapse Load for Vessel With External Flaw Simultaneously Subjected to Internal Pressure and External Bending Moment-Experimental and FEA Results
,”
ASME J. Pressure Vessel Technol.
0094-9930,
131
, p.
021206
.
9.
Konosu
,
S.
, and
Oyamada
,
K.
, 2007, “
Development of Simplified Plastic Collapse Assessment Procedure for Vessel With Internal Surface Flaw
,”
ASME
Paper No. PVP2007-26437.
10.
ASME
2004, Boiler and Pressure Vessel Code, Section VIII, Div. 2, Appendix 6, 6-153.
11.
2006, “
Assessment Standard for Externally Corroded Pressure Equipment
,” Ibaraki FFS Rule, Ibaraki Prefecture of Japan, in Japanese.
12.
ASME
, 2003, “
Requirements for Analytical Evaluation of Pipe Wall Thinning
,” ASME B&PV Sec. XI, Div. 1, ASME Code Case N-597-2.
13.
Gerber
,
T. L.
,
Deardorff
,
A. F.
,
Norris
,
D. M.
, and
Lucas
,
W. F.
, 1992, “
Acceptance Criteria for Structural Evaluation of Erosion-Corrosion Thinning in Carbon Steel Piping
,”
Nucl. Eng. Des.
0029-5493,
133
(
1
), pp.
31
36
.
14.
Scarth
,
D. A.
,
Hasegawa
,
K.
,
Goyette
,
L. F.
, and
Rush
,
P.
, 2006, “
Supplementary Technical Basis for ASME Section XI Code Case N-597-2
,”
ASME
Paper No. PVP2006-ICPVT-11-93278.
15.
Dassault Systemes Simulia Corp.
, ABAQUS, Finite Element Computer Program, Version 6.4-1 and 6.6-3.
You do not currently have access to this content.