Abstract

This paper discusses the use of self-consolidating concrete (SCC), in a large-scale placement during new nuclear plant construction. SCC has provided cost and labor savings and construction process improvements. Use of SCC has been effective in schedule acceleration by reducing placement durations and early curing termination with rapid strength gain. Self-consolidating properties were particularly of value at placements of poor access as internal vibrators were not effective and large surface area made form vibrators ineffective beyond the perimeter. This paper provides a discussion of technical challenges encountered in development of a properly functioning SCC mixture, and testing performed to overcome these challenges. The paper discusses the engineering considerations and laboratory and field trials preparing for a 3950 m3 placement for the base of a nuclear plant. The placement was anticipated to take 35 h at 110 m3/h batch plant output. Overview of mix design specifications and mix development is provided. The mixture satisfied the laboratory test parameters including SCC tests; stability and column segregation. However, the mixture had to undergo rounds of constructability testing beyond laboratory development prior to the large placement. Among the constructability properties was the distance SCC will move with the stone before stopping. A long trough was filled as a mockup for and subsequently cored. The number of pumps and pump nozzle placement spacing was determined as a result. Slump flow retention as the polycarboxylate loses effectiveness and foaming of the mixture when pumped were also investigated. Foaming was attributed to viscosity, air entrainer, and pump pressures or rate of pumping. Laboratory trials with various admixtures and pumping studies in the field were conducted to achieve a mixture that retains slump flow and can be pumped at the desired rates without instability or excessive foaming. The placement was completed successfully in 35 h over multiple shifts.

References

1.
ASTM
,
2009
, “
Standard Specification for Portland Cement
,”
ASTM International
, West Conshohocken, PA, Standard No. ASTM C150/C150M-09.
2.
ASTM
,
2008
, “
Standard Specification for Coal Fly Ash and Raw or Calcinated Natural Pozzolan for Use in Concrete
,”
ASTM International
, West Conshohocken, PA, Standard No. ASTM C618-08a.
3.
ASTM
,
2010
, “
Standard Specification for Chemical Admixtures for Concrete
,”
ASTM International
, West Conshohocken, PA, Standard No. ASTM C494/C494M-10a.
4.
ASTM
,
2010
, “
Standard Specification for Air-Entraining Admixtures for Concrete
,”
ASTM International
, West Conshohocken, PA, Standard No. ASTM C260/C260M-10a.
5.
ASTM
,
2009
, “
Standard Test Method for Slump Flow of Self-Consolidating Concrete
,”
ASTM International
, West Conshohocken, PA, Standard No. ASTM C1611/C1611M-09b.
6.
ASTM
,
2010
, “
Standard Test Method for Static Segregation of Self-Consolidating Concrete Using Column Technique
,”
ASTM International
, West Conshohocken, PA, Standard No. ASTM C1610/C1610M-10.
7.
ACI
,
2001
, “
Code Requirements for Nuclear Safety Related Concrete Structures
,”
American Concrete Institute
, Farmington Hills, MI, Standard No. ACI
349
01
.
8.
ASTM
,
2010
, “
Standard Specification for Ready-Mixed Concrete
,”
ASTM International
, West Conshohocken, PA, Standard No. ASTM C94/C94M-10.
9.
ASTM
,
2007
, “
Standard Practice for Making and Curing Concrete Test Specimens in the Laboratory
,”
ASTM International
, West Conshohocken, PA, Standard No. ASTM C192/C192M-07.
10.
ACI
,
1991
, “
Standard Practice for Selecting Proportions for Normal, Heavyweight, and Mass Concrete
,”
American Concrete Institute
, Farmington Hills, MI, Standard No. ACI 211.1-91.
11.
ACI
,
2007
, “
Self–Consolidating Concrete
,”
American Concrete Institute
, Farmington Hills, MI, Standard No. ACI 237R-07.
12.
ACI
,
2005
, “
Specifications for Structural Concrete
,”
American Concrete Institute
, Farmington Hills, MI, Standard No. ACI
301
05
.
13.
ASTM
,
2008
, “
Standard Test Method for Time of Setting of Concrete Mixtures by Penetration Resistance
,”
ASTM International
, West Conshohocken, PA, Standard No. ASTM C403/C403M-08.
14.
ASTM
,
2009
, “
Standard Test Method for Passing Ability of Self-Consolidating Concrete by J-Ring
,”
ASTM International
, West Conshohocken, PA, Standard No. ASTM C1621/C1621M-09b.
15.
ASTM
,
2008
, “
Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
,”
ASTM International
, West Conshohocken, PA, Standard No. ASTM C1064/C1064M-08.
You do not currently have access to this content.