Skip Nav Destination
Issues
March 2013
ISSN 1932-6181
EISSN 1932-619X
In this Issue
Research Paper
High Sensitive Force Sensing Based on the Optical Fiber Coupling Loss
J. Med. Devices. March 2013, 7(1): 011001.
doi: https://doi.org/10.1115/1.4023264
Topics:
Sensors
,
Optical fiber
,
Fibers
Material Handling System for Robotic Natural Orifice Surgery
J. Med. Devices. March 2013, 7(1): 011003.
doi: https://doi.org/10.1115/1.4023265
A Portable Atmospheric Air Plasma Device for Biomedical Treatment Applications
J. Med. Devices. March 2013, 7(1): 011007.
doi: https://doi.org/10.1115/1.4023498
Topics:
Biomedicine
,
Plasma devices
,
Plasma jets
,
Plasmas (Ionized gases)
,
Cooling
,
Probes
,
Temperature
Radio Frequency Identification as a Testbed for Integration of Low Frequency Radio Frequency Sensors Into Orthopedic Implants
J. Med. Devices. March 2013, 7(1): 011008.
doi: https://doi.org/10.1115/1.4023499
Topics:
Orthopedics
,
Sensors
,
Robustness
,
Bone
,
Mechanical properties
,
Failure
Sagittal Bone Saw With Orbital Blade Motion for Improved Cutting Efficiency
J. Med. Devices. March 2013, 7(1): 011009.
doi: https://doi.org/10.1115/1.4023500
Research Papers
Performance of Biopsy Needle With Therapeutic Injection System to Prevent Bleeding Complications
J. Med. Devices. March 2013, 7(1): 011002.
doi: https://doi.org/10.1115/1.4023274
Computational Fluid Dynamics Evaluation of Equivalency in Hemodynamic Alterations Between Driver, Integrity, and Similar Stents Implanted Into an Idealized Coronary Artery
J. Med. Devices. March 2013, 7(1): 011004.
doi: https://doi.org/10.1115/1.4023413
Topics:
Stents
,
Computational fluid dynamics
,
Vessels
,
Flow (Dynamics)
Development and Evaluation of Drug Eluting Stent Having Biphasic Release From a Single Layer of Biodegradable Polymer
Ashok Thakkar, Ankur Raval, Ramila Mandal, Sanjay Parmar, Arpit Jariwala, Jaynish Tailor, Anita Mehta
J. Med. Devices. March 2013, 7(1): 011005.
doi: https://doi.org/10.1115/1.4023414
Topics:
Coating processes
,
Coatings
,
Drugs
,
Polymers
,
Stents
,
Biodegradation
Battery-Less Wireless Instrumented Knee Implant
J. Med. Devices. March 2013, 7(1): 011006.
doi: https://doi.org/10.1115/1.4023412
Topics:
Capacitance
,
Capacitors
,
Design
,
Energy consumption
,
Energy harvesting
,
Knee
,
Knee joint prostheses
,
Sensors
,
Storage
,
Stress
A Simple Goniometer for Use Intraoperatively in Total Knee Arthroplasty
J. Med. Devices. March 2013, 7(1): 011010.
doi: https://doi.org/10.1115/1.4023289
Topics:
Arthroplasty
,
Knee
,
Navigation
,
Errors
,
Surgery
,
Computers
Technical Briefs
Design of a New Portable Cryostorage Device
J. Med. Devices. March 2013, 7(1): 014501.
doi: https://doi.org/10.1115/1.4023275
Design Innovation Paper
A New Surgical Device for Minimally Invasive “Core-Out” Excision of High Fistula-in-Ano
J. Med. Devices. March 2013, 7(1): 015001.
doi: https://doi.org/10.1115/1.4023130
Topics:
Biological tissues
,
Blades
,
Cutting
,
Screws
,
Design
,
Surgery
,
Manufacturing
Email alerts
RSS Feeds
Design and Experiment Research of a Novel Retrievable Peripheral Vascular Stent
J. Med. Devices (August 2023)
SW-SiStA2: A New-Generation Semi-Wearable Device for Sit-to-Stand Assistance
J. Med. Devices (August 2023)
Design of the Novel Single Incision, Free Motion Laparoscopic Surgical System
J. Med. Devices (June 2023)
Development of an Endotracheal Tube Cap for Oxygen Delivery During Intubation
J. Med. Devices (June 2023)