An actuated handheld force-feedback controlled ultrasound probe has been developed. The controller maintains a prescribed contact force between the probe and a patient’s body. The device will enhance the diagnostic capability of free-hand elastography, swept-force compound imaging and make it easier for a technician to acquire repeatable (i.e., directly comparable) images over time. The mechanical system consists of an ultrasound probe, a ball-screw-driven linear actuator, and a force/torque sensor. The feedback controller commands the motor to rotate the ball screw to translate the ultrasound probe in order to maintain a desired contact force. In preliminary user studies, it was found that the control system maintained a constant contact force with 1.7 times less variation than human subjects provided with a visual force display. Users without a visual force display were only able to maintain a constant force with 20 times worse variation than the automatic controller. The system was also used to determine the viscoelastic properties of soft tissues.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Handheld Force Controlled Ultrasound Probe
Matthew Gilbertson,
Matthew Gilbertson
Massachusetts Institute of Technology
Search for other works by this author on:
Brian Anthony,
Brian Anthony
Massachusetts Institute of Technology
Search for other works by this author on:
Shih-Yu Sun
Shih-Yu Sun
Massachusetts Institute of Technology
Search for other works by this author on:
Matthew Gilbertson
Massachusetts Institute of Technology
Brian Anthony
Massachusetts Institute of Technology
Shih-Yu Sun
Massachusetts Institute of Technology
J. Med. Devices. Jun 2010, 4(2): 027540 (1 pages)
Published Online: August 12, 2010
Article history
Published:
August 12, 2010
Citation
Gilbertson, M., Anthony, B., and Sun, S. (August 12, 2010). "Handheld Force Controlled Ultrasound Probe." ASME. J. Med. Devices. June 2010; 4(2): 027540. https://doi.org/10.1115/1.3454860
Download citation file:
Get Email Alerts
Cited By
Context-Driven Design of a Laparoscopic Instrument Cleaner for Use in Rural Low-Resource Hospitals
J. Med. Devices (March 2025)
Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles
J. Med. Devices (December 2024)
Review of Blood and Fluid Warming Methods
J. Med. Devices (December 2024)
Related Articles
A New Actuation System With Simulated Electrocardiogram Signal for MR Elastography
J. Med. Devices (June,2010)
A μ -Synthesis Based Control for Compliant Maneuvers
J. Dyn. Sys., Meas., Control (December,2006)
Mechanical Design for Modularity of Laparoscopic Tools
J. Med. Devices (June,2008)
Development and Performance of a Controllable Autoloading Needle-Free Jet Injector
J. Med. Devices (March,2011)
Related Proceedings Papers
Related Chapters
QP Based Encoder Feedback Control
Robot Manipulator Redundancy Resolution
Fault-Tolerant Control of Sensors and Actuators Applied to Wind Energy Systems
Electrical and Mechanical Fault Diagnosis in Wind Energy Conversion Systems
An Intelligent Control System Based on FPGA for Telephone Communication Network
International Conference on Electronics, Information and Communication Engineering (EICE 2012)