Although hand prostheses with a cosmetic covering are commercially available for disabled people, the operating effort due to the stiffness of the mechanism is high. This results in high power requirements. This paper aims to present a new concept of mechanisms for the compensation of the nonlinear stiffness of hand prostheses by using statically balanced mechanisms with a nonlinear behavior. This concept was based on a combination of stability phases of snap-through buckling in bistable spring mechanisms to create the nonlinear balancing force. To demonstrate the efficiency of the concept, an optimized design for a case study of a child-sized hand prosthesis is also presented. A pattern search method was applied for the optimization. As a result, the calculated stiffness and, thereby, the operating effort was reduced by 96%. It can be concluded from the conceptual and numerical results that the presented concept provides a highly efficient solution to the discussed problem.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Stiffness Compensation in Hand Prostheses With Cosmetic Coverings Using Statically Balanced Mechanisms
Ali Asadi Nikooyan,
Ali Asadi Nikooyan
Delft University of Technology
Search for other works by this author on:
Dick Plettenburg,
Dick Plettenburg
Delft University of Technology
Search for other works by this author on:
Just Herder
Just Herder
Delft University of Technology
Search for other works by this author on:
Nima Tolou
Delft University of Technology
Gerwin Smit
Delft University of Technology
Ali Asadi Nikooyan
Delft University of Technology
Dick Plettenburg
Delft University of Technology
Just Herder
Delft University of Technology
J. Med. Devices. Jun 2010, 4(2): 027527 (1 pages)
Published Online: August 10, 2010
Article history
Published:
August 10, 2010
Citation
Tolou, N., Smit, G., Nikooyan, A. A., Plettenburg, D., and Herder, J. (August 10, 2010). "Stiffness Compensation in Hand Prostheses With Cosmetic Coverings Using Statically Balanced Mechanisms." ASME. J. Med. Devices. June 2010; 4(2): 027527. https://doi.org/10.1115/1.3443321
Download citation file:
547
Views
Get Email Alerts
Cited By
Experimental Investigation of the Calcified Plaque Material Removal Rate in Coronary Rotational Atherectomy
J. Med. Devices (December 2023)
A Novel Design Method for the Knee Joint of the Exoskeleton Based on the Modular Wearable Sensor
J. Med. Devices (December 2023)
Assessment of a Novel Application of the Capture-Trap-Terminate Approach for Treating Aerosol Products During Dental Procedures
J. Med. Devices (December 2023)
Related Articles
A New External Fixator Design for Femoral Fracture Reduction
J. Med. Devices (June,2008)
Synthetic Soft Tissue Characterization of the Mechanical Analogue Lumbar Spine
J. Med. Devices (June,2008)
Special Section: Annual Education Issue: Let the Wild Rumpus of Education Start!
J Biomech Eng (July,2016)
Design of a Dynamic Stabilization Spine Implant
J. Med. Devices (June,2009)
Related Proceedings Papers
Related Chapters
Elastic Constant Used in Continuum-Based Adhesion Models
International Symposium on Information Engineering and Electronic Commerce, 3rd (IEEC 2011)
Spring Constants of Elastic Shapes in Contact
Applying the ASME Codes: Plant Piping & Pressure Vessels (Mister Mech Mentor, Vol. 2)
Vibration Analysis of the Seated Human Body in Vertical Direction
International Conference on Computer Technology and Development, 3rd (ICCTD 2011)