Accurate detection and classification of heart murmurs by auscultation is suboptimal and not always definitive. The murmur information perceived by the physician brain is the combined effect of both patient's (human) heart and the physician's ear. The information containing the murmur characterization which is retrieved by the human brain resides in the electrical signal coming out of the cochlea. For the very reasons described here, cochlea-like processing has been successfully applied to multiple speech recognition related technologies. This had not, before our prior work, been applied to human heart murmur analysis. Our prior research consisted of three steps: (1) capturing heart sounds, (2) processing the sounds using a cochlea-like filter, and then, (3) classifying each sound as being normal or a murmur using an artificial neural network (ANN). Previously in our research, we used a static cochlea-like filter model in step 2 as described above, which resulted a significant improvement in terms of accuracy of heart murmur classification. Our cochlear filter analysis helped identify information-rich frequency segments in human heart sound. We want to advance the cochlear filter model from a static to a variable frequency selective model with feedback from ANN for better optimization of the heart murmur classification. The heart sounds will be processed in ways more closely replicating the human cochlea than the static cochlear filter. A variable self optimizing cochlear filter will better reproduce the mechanism of the human cochlea in that it will contain a feedback system from ANN to cochlear processing to automatically select the most useful frequencies based upon a threshold mechanism filtering out those frequencies which do not contain significantly useful information about classification of heart murmur. The output of the sounds in the frequency range remaining (variable self-optimizing cochlear filtered sounds) may then be used by the neural network to make a final decision about murmur classification. Our hypothesis is that a variable self-optimizing cochlear filter will significantly improve the accuracy in classification of heart sounds as normal or murmur when compared to a static cochlear filter. Using this approach, we plan to develop an AI based system which will classify heart sounds with a success rate significantly better than the static cochlear filter previously developed.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Variable Self-Optimizing Cochlear Model for Heart Murmur Detection/Classification
W. Ahmad,
W. Ahmad
Department of Electrical and Computer Engineering,
University of Minnesota
, Duluth
Search for other works by this author on:
G. Nordehn,
G. Nordehn
Department of Family and Community Health,
University of Minnesota
, Medical School Duluth
Search for other works by this author on:
J. L. Fitzakerley
J. L. Fitzakerley
Department of Physiology and Pharmacology,
University of Minnesota
, Medical School Duluth
Search for other works by this author on:
W. Ahmad
Department of Electrical and Computer Engineering,
University of Minnesota
, Duluth
G. Nordehn
Department of Family and Community Health,
University of Minnesota
, Medical School Duluth
J. L. Fitzakerley
Department of Physiology and Pharmacology,
University of Minnesota
, Medical School DuluthJ. Med. Devices. Jun 2009, 3(2): 027541 (1 pages)
Published Online: July 9, 2009
Article history
Published:
July 9, 2009
Citation
Ahmad, W., Hayee, M. I., Nordehn, G., Burns, S., and Fitzakerley, J. L. (July 9, 2009). "Variable Self-Optimizing Cochlear Model for Heart Murmur Detection/Classification." ASME. J. Med. Devices. June 2009; 3(2): 027541. https://doi.org/10.1115/1.3147531
Download citation file:
552
Views
Get Email Alerts
Cited By
Validation of a Repurposed pH Monitoring Capsule for Cecal Applications Using Novel Synthetic Cecal Contents
J. Med. Devices (March 2025)
Related Articles
Cardiac Arrest Alert System
J. Med. Devices (June,2009)
Heart Murmur Detection∕Classification System Using Cochlea-Like Pre-Processing
J. Med. Devices (June,2008)
Optical System Design of Laser-Based Stethoscope
J. Med. Devices (June,2011)
Detection of Self-Stimulatory Behaviors of Children with Autism Using Wearable and Environmental Sensors
J. Med. Devices (June,2009)
Related Chapters
A Review on Prediction over Pressured Zone in Hydrocarbon Well Using Seismic Travel Time through Artificial Intelligence Technique for Pre-Drilling Planing
International Conference on Software Technology and Engineering, 3rd (ICSTE 2011)
Spiking Neural Networks on Self-Updating System-on-Chip for Autonomous Control
International Conference on Mechanical Engineering and Technology (ICMET-London 2011)
Role of Artificial Intelligence in Hepatitis B Diagnosis
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3