The number of osteoporotic hip fractures is projected to increase two to three fold in the next . This will lead to increased mortality and nursing home placement with significant costs to our society. Although in clinical trials drug and hormone therapies have shown an important decrease in fracture risk there is a significant role of surgical implantation treatments to further reduce the risk in specific subpopulations. Strength testing was completed on four pairs of osteoporotic, two pairs of osteopenic, and two pairs of normal cadaver femurs. The fracturing was recorded with a video camera at 4000 frames per second. The specially designed test fixture was instrumented with three load cells to measure the femoral forces. Force and moment data were recorded simultaneously and correlated with the frames. The fracture force at the greater trochanter was used to characterize the strength of implanted∕nonimplanted osteoporotic femurs. All femurs began fracturing within about at a test speed of . During the first , the relationship between force and displacement was nonlinear, but linear thereafter until the fracture occurs. The fracture events resolved completely within . The average strength increase of the implanted femurs was 79% compared to the nonimplanted controls. The simultaneous acquisition of fracture images and load data is a powerful tool to understand and characterize numerically the femoral fracture. This methodology allows the researcher to define the best metrics to compare competing reinforcement materials, implant designs and surgical procedures.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
PMMA Implants Increase Femoral Strength
Dan Dragomir-Daescu,
Dan Dragomir-Daescu
Mayo Clinic
, Rochester, MN, USA
Search for other works by this author on:
Mark E. Bolander,
Mark E. Bolander
Mayo Clinic
, Rochester, MN, USA
Search for other works by this author on:
Kevin E. Bennet,
Kevin E. Bennet
Mayo Clinic
, Rochester, MN, USA
Search for other works by this author on:
James T. Bronk,
James T. Bronk
Mayo Clinic
, Rochester, MN, USA
Search for other works by this author on:
Sean McEligot
Sean McEligot
Mayo Clinic
, Rochester, MN, USA
Search for other works by this author on:
Dan Dragomir-Daescu
Mayo Clinic
, Rochester, MN, USA
Mark E. Bolander
Mayo Clinic
, Rochester, MN, USA
Kevin E. Bennet
Mayo Clinic
, Rochester, MN, USA
James T. Bronk
Mayo Clinic
, Rochester, MN, USA
Sean McEligot
Mayo Clinic
, Rochester, MN, USAJ. Med. Devices. Jun 2008, 2(2): 027552 (1 pages)
Published Online: June 25, 2008
Article history
Published:
June 25, 2008
Citation
Dragomir-Daescu, D., Bolander, M. E., Bennet, K. E., Bronk, J. T., and McEligot, S. (June 25, 2008). "PMMA Implants Increase Femoral Strength." ASME. J. Med. Devices. June 2008; 2(2): 027552. https://doi.org/10.1115/1.2934345
Download citation file:
467
Views
Get Email Alerts
Cited By
Context-Driven Design of a Laparoscopic Instrument Cleaner for Use in Rural Low-Resource Hospitals
J. Med. Devices (March 2025)
Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles
J. Med. Devices (December 2024)
Review of Blood and Fluid Warming Methods
J. Med. Devices (December 2024)
Related Articles
Novel re-entrant porous composite structure: a potential for orthopaedic applications
J. Med. Devices (June,2008)
Human Joint Simulation Using LifeMOD Co-Simulation
J. Med. Devices (June,2008)
Real-Time, In Vivo Measurement of Contact Pressures at a Knee Arthroplasty
J. Med. Devices (June,2009)
A New Cemented Hip Prosthesis Concept
J. Med. Devices (June,2011)
Related Proceedings Papers
Related Chapters
Introduction and Scope
High Frequency Piezo-Composite Micromachined Ultrasound Transducer Array Technology for Biomedical Imaging
Applications of Macro-, Micro- and Nano-Biomaterials Prepared using Biopolymers
Biopolymers Based Micro- and Nano-Materials
mDFA Human Empirical Results
Modified Detrended Fluctuation Analysis (mDFA)