Loading of dental implants immediately after placement is an important attribute for the patients receiving the implants, but may induce a failure in the osseointegration of the implant. Even though the loading required to induce such failures is currently unknown, it is estimated that the osseointegration may fail if an implant is luxated in bone by more than 50μm. Therefore, the ability to measure this loading can provide the practicing dentist with critical information in estimating the functional life of a newly placed implant. This paper discusses the design and fabrication of a cost-effective test setup for measuring the amount of horizontal force required to displace a nonosseointegrated implant, and presents the results of our pilot in vitro load measurements for dental implants mounted in a bovine mandible. Although the sample size of our measurements is not statistically significant, the initial data show that the amount of horizontal force required to displace a 4.3×13mm implant by 50μm is in the order of 150N, and therefore the implant may fail to osseointegrate for biting forces that are as low as 440N, which is about half of the typical biting force of an adult in the molar area. One implication of our study is that implants having smaller diameters may move and fail to osseointegrate for even lower biting forces. Furthermore, our work represents the first steps in developing appropriate metrics to correlate the measured biting force generated by a patient with his or her candidacy for immediate functional implant loading.

1.
Szmukler-Moncler
,
S.
,
Salama
,
H.
,
Reingewirtz
,
Y.
, and
Dubruille
,
J.
, 1998, “
Timing of Loading and Effect of Micromotion on Bone-Dental Implant Interface: Review of Experimental Literature
,”
J. Biomed. Mater. Res.
0021-9304,
2
(
43
), pp.
192
203
.
2.
Brunski
,
J.
, 1999, “
In Vivo Bone Response to Biomechanical Loading at the Bone∕Dental Implant Interface
,”
Adv. Dent. Res.
0895-9374,
13
, pp.
99
119
.
3.
Isidor
,
F.
, 2006, “
Influences of Forces on Peri-Implant Bone
,”
Clin. Oral Implants Res.
0905-7161,
3
(
17
), pp.
8
18
.
4.
Gibbs
,
C.
,
Anusavice
,
K.
,
Young
,
H.
,
Jones
,
J.
, and
Esquivel-Upshaw
,
J.
, 2002, “
Maximum Clenching Force of Patients With Moderate Loss of Posterior Tooth Support: A Pilot Study
,”
J. Prosthet. Dent.
0022-3913,
5
(
88
), pp.
498
502
.
5.
Payne
,
A. G.
,
Tawse-Smith
,
A.
,
Kumara
,
R.
, and
Thomson
,
W. M.
, 2001, “
One-Year Prospective Evaluation of the Early Loading of Unsplinted Conical Branemark Fixtures With Mandibular Overdentures Immediately Following Surgery
,”
Clin. Implant Dent. Relat. Res.
,
1
(
3
), pp.
9
19
.
6.
Richter
,
E.
, 1995, “
In Vivo Vertical Forces on Implants
,”
Int. J. Oral Maxillofac Implants
0882-2786,
1
(
10
), pp.
99
108
.
7.
Wohrle
,
P. S.
, 1998, “
Single-Tooth Replacement in the Aesthetic Zone With Immediate Provisionalization: Fourteen Consecutive Case Reports
,”
Pract. Periodontics Aesthet Dent.
1042-2722,
10
(
9
), pp.
1107
1114
.
8.
Kupeyan
,
H.
, and
May
,
K.
, 1998, “
Implant and Provisional Crown Placement: A One Stage Protocol
,”
Implant Dent.
1056-6163,
7
, pp.
213
219
.
9.
Andersen
,
E.
,
Haanaes
,
H.
, and
Knutsen
,
B.
, 2002, “
Immediate Loading of Single-Tooth ITI Implants in the Anterior Maxilla: A Prospective 5‐Year Pilot Study
,”
Clin. Oral Implants Res.
0905-7161,
13
(
3
), pp.
281
287
.
10.
Schnitman
,
P.
,
Wohrle
,
P.
,
Rubenstein
,
J.
,
Silve
,
J.
, and
Wang
,
N.-H.
, 1997, “
Ten Year Results for Branemark Implants Immediately Loaded With Fixed Prostheses at Implant Placement
,”
Int. J. Oral Maxillofac Implants
0882-2786,
12
(
4
), pp.
495
503
.
11.
Gatti
,
C.
,
Haefliger
,
W.
, and
Chiapasco
,
M.
, 2000, “
Implant-Retained Mandibular Overdentures With Immediate Loading: A Prospective Study of ITI Implants
,”
Int. J. Oral Maxillofac Implants
0882-2786,
3
(
15
), pp.
383
388
.
12.
Gross
,
M.
, and
Laufer
,
B.
, 1997, “
Splinting Osseointegrated Implants and Natural Teeth in Rehabilitation of Partially Edentulous Patients. Part I: Laboratory and Clinical Studies
,”
J. Oral Rehabil.
0305-182X,
11
(
24
), pp.
863
870
.
13.
National Instruments, 2006, LABVIEW, Austin, TX.
You do not currently have access to this content.