1-1 of 1
Keywords: particle volume fraction
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Heat Mass Transfer. November 2011, 133(11): 111501.
Published Online: August 31, 2011
.... The results indicate that at comparatively low heat fluxes, there is deterioration in boiling heat transfer with very low particle volume fraction of 0.01%, and it increases with volume fraction and shows enhancement with 0.1%. However, the behavior is the other way around at high heat fluxes. The enhancement...