In this paper, experiments were conducted to achieve a better understanding of the oscillating heat pipe (OHP) operating behavior with water and ethanol as working fluid. The experimental results showed that there existed a necessary temperature difference between the evaporator and the condenser section to keep the heat pipe working. The maximum effective conductivity of the water OHP reached up to 259kW/mK, while that of the ethanol OHP is of 111kW/mK. Not all the OHPs are operated in the horizontal operation mode. The heat transfer performance of the ethanol OHP was obviously affected by the filling ratio and the inclination angle but the influence law is irregular. The effect of the filling ratio and the inclination angle of the water OHP were smaller than that of the ethanol one. The heat transfer performance of the OHP was improved with increase of operating temperature. The startup characteristics of the OHP depended on the establishment of the integral oscillating process, which was determined by the operating factors. The startup temperature of the ethanol OHP varied from 40°C to 50°C and that of the water, OHP varied from 40°C to 60°C without considering the horizontal operating mode. The water OHP showed a better performance and more stable heat transfer characteristics than the ethanol OHP, which had no obvious advantages of the startup capability as well.

1.
Miyazaki
,
Y.
, and
Akachi
,
H.
, 1996, “
Heat Transfer Characteristics of Looped Capillary Heat Pipe
,”
Proceedings of the Fifth International Heat Pipe Symposium
, Melbourne, Australia, pp.
378
383
.
2.
Akachi
,
H.
,
Polasek
,
F.
, and
Stulc
,
P.
, 1996, “
Pulsating Heat Pipes
,”
Proceedings of the Fifth International Heat Pipe Symposium
, Melbourne, Australia, pp.
208
217
.
3.
Charoensawan
,
P.
,
Khandekar
,
S.
,
Groll
,
M.
, and
Terdtoon
,
P.
, 2003, “
Closed Loop Pulsating Heat Pipes, Part A: Parametric Experimental Investigations
,”
Appl. Therm. Eng.
1359-4311,
23
(
16
), pp.
2009
2020
.
4.
Khandekar
,
S.
,
Charoensawan
,
P.
,
Groll
,
M.
, and
Terdtoon
,
M.
, 2003, “
Closed Loop Pulsating Heat Pipes, Part B: Visualization and Semi-Empirical Modeling
,”
Appl. Therm. Eng.
1359-4311,
23
(
16
), pp.
2021
2033
.
5.
Xu
,
J.
,
Li
,
Y.
, and
Wong
,
T.
, 2005, “
High Speed Flow Visualization of a Closed Loop Pulsating Heat Pipe
,”
Int. J. Heat Mass Transfer
0017-9310,
48
(
16
), pp.
3338
3351
.
6.
Ma
,
H. B.
,
Wilson
,
C.
,
Borgmeyer
,
B.
,
Park
,
K.
, and
Yu
,
Q.
, 2006, “
Effect of Nanofluid on the Heat Transport Capability in an Oscillating Heat Pipe
,”
Appl. Phys. Lett.
0003-6951,
88
, p.
143116
.
7.
Xian
,
H.
,
Liu
,
D.
,
Yang
,
Y.
,
Shang
,
F.
,
Du
,
X.
,
Mujumdar
,
A.
, and
Huang
,
L.
, 2007, “
Study on Heat Transfer Enhancement of Oscillating-Flow Heat Pipe for Drying
,”
Drying Technol.
0737-3937,
25
(
4
), pp.
723
729
.
8.
Holley
,
B.
, and
Faghri
,
A.
, 2005, “
Analysis of Pulsating Heat Pipe With Capillary Wick and Varying Channel Diameter
,”
Int. J. Heat Mass Transfer
0017-9310,
48
(
13
), pp.
2635
2651
.
9.
Xian
,
H.
,
Liu
,
D.
,
Yang
,
Y.
,
Shang
,
F.
, and
Du
,
X.
, 2007, “
Study on the Heat Transfer Enhancement of Oscillating-Flow Heat Pipe by Pulse Heating
,”
J. Enhanced Heat Transfer
1065-5131,
14
(
1
), pp.
53
64
.
10.
Gi
,
K.
,
Maezawa
,
S.
,
Kojima
,
Y.
, and
Yamazaki
,
N.
, 1999, “
CPU Cooling of Notebook PC by Oscillating Heat Pipe
,”
Proceedings of the 11th International Heat Pipe Conference
, Tokyo, Japan, pp.
166
169
.
11.
Rittidech
,
S.
,
Dangeton
,
W.
, and
Soponronnarit
,
S.
, 2005, “
Close-Ended Oscillating Heat-Pipe (CEOHP) Air-Preheater for Energy Thrift in a Dryer
,”
Appl. Energy
0306-2619,
81
(
2
), pp.
198
208
.
12.
Rittidech
,
S.
, and
Wannapakne
,
S.
, 2007, “
Experimental Study of the Performance of a Solar Collector by Closed-End Oscillating Heat Pipe (CEOHP)
,”
Appl. Therm. Eng.
1359-4311,
27
(
11–12
), pp.
1978
1985
.
13.
Han
,
X.
,
Ma
,
H.
,
Jiao
,
A.
, and
Critser
,
J.
, 2008, “
Investigations on the Heat Transport Capability of a Cryogenic Oscillating Heat Pipe and Its Application in Achieving Ultra-Fast Cooling Rates for Cell Vitrification Cryopreservation
,”
Cryobiology
0011-2240,
56
(
3
), pp.
195
203
.
You do not currently have access to this content.