Syngas, an environmentally friendly alternative gaseous fuel for internal combustion engine operation, mainly consists of carbon monoxide (CO) and hydrogen (H2). It can substitute fossil diesel oil in a compression ignition diesel engine through dual fuel operation route. In the present investigation, experiments were conducted in a constant speed single cylinder direct injection diesel engine fuelled with syngas-diesel in a dual fuel operation mode. The main contribution of this study is to introduce the new synthetic gaseous fuel (syngas) including the possible use of CO gas, an alternative diesel engine fuel. In this work, four different H2 and CO compositions of syngas were chosen for dual fuel study under different engine loading levels. Keeping the same power output at the corresponding tested loads, the engine performance of dual fuel operations were compared to that of diesel mode for the entire load range. The maximum diesel replacement in the engine was found to be 72.3% for 100% H2 fuel. This amount replacement rate was reduced for the low energetic lower H2 content fuels. The brake thermal efficiency was always found highest (about 21%) in the case of diesel mode operation. However, the 100% H2 syngas showed a comparative performance level with diesel mode at the expense of higher NOx emissions. At 80% engine load, the brake thermal efficiency was found to be 15.7% for 100% CO syngas. This value increased to 16.1%, 18.3% and 19.8% when the 100% CO syngas composition was replaced by H2 contents of 50%, 75% and 100%, respectively. At part loads (i.e., at 20% and 40%), dual fuel mode resulted a poor performance including higher emission levels. In contrast, at higher loads, syngas fuels showed a good competitive performance to diesel mode. At all the tested loads, the NOx emission was observed highest for 100% H2 syngas as compared to other fuel conditions, and a maximum of 240 ppm was found at 100% load. However, when the CO fractions of 25%, 50% and 100%, were substituted to hydrogen fuel, the emission levels got reduced to 175 ppm, 127 ppm, and 114 ppm, respectively. Further, higher CO and HC emission levels were recorded for 25%, 50%, and 100% CO fraction syngas fuels due to their CO content. Ignition delay was found to increase for the dual fuel operation as compared to diesel mode, and also it seemed to be still longer for higher H2 content syngas fuels. The peak pressure and maximum rate of pressure rise were found to decrease for all the cases of dual fuel operation, except for 100% H2 syngas (beyond 60% load). The reduction in peak pressure resulted a rise in the exhaust gas temperature at all loads under dual fuel operation. The present investigation provides some useful experimental data which can be applied to the possible existing engine parameters modifications to produce a competitive syngas dual fuel performance at all the loading operations.
Skip Nav Destination
e-mail: saha@iitg.ernet.in
Article navigation
December 2011
Research Papers
Effect of Load Level on the Performance of a Dual Fuel Compression Ignition Engine Operating on Syngas Fuels With Varying H2/CO Content
B. B. Sahoo,
B. B. Sahoo
Research scholar
Centre for Energy,
Indian Institute of Technology Guwahati
, Guwahati–781 039, India
Search for other works by this author on:
U. K. Saha,
U. K. Saha
Associate Professor
Department of Mechanical Engineering,
e-mail: saha@iitg.ernet.in
Indian Institute of Technology Guwahati
, Guwahati–781 039, India
Search for other works by this author on:
N. Sahoo
N. Sahoo
Associate Professor
Department of Mechanical Engineering,
Indian Institute of Technology Guwahati
, Guwahati–781 039, India
Search for other works by this author on:
B. B. Sahoo
Research scholar
Centre for Energy,
Indian Institute of Technology Guwahati
, Guwahati–781 039, India
U. K. Saha
Associate Professor
Department of Mechanical Engineering,
Indian Institute of Technology Guwahati
, Guwahati–781 039, India
e-mail: saha@iitg.ernet.in
N. Sahoo
Associate Professor
Department of Mechanical Engineering,
Indian Institute of Technology Guwahati
, Guwahati–781 039, India
J. Eng. Gas Turbines Power. Dec 2011, 133(12): 122802 (12 pages)
Published Online: August 29, 2011
Article history
Received:
July 1, 2010
Revised:
March 23, 2011
Online:
August 29, 2011
Published:
August 29, 2011
Citation
Sahoo, B. B., Saha, U. K., and Sahoo, N. (August 29, 2011). "Effect of Load Level on the Performance of a Dual Fuel Compression Ignition Engine Operating on Syngas Fuels With Varying H2/CO Content." ASME. J. Eng. Gas Turbines Power. December 2011; 133(12): 122802. https://doi.org/10.1115/1.4003956
Download citation file:
Get Email Alerts
Shape Optimization of an Industrial Aeroengine Combustor to reduce Thermoacoustic Instability
J. Eng. Gas Turbines Power
Dynamic Response of A Pivot-Mounted Squeeze Film Damper: Measurements and Predictions
J. Eng. Gas Turbines Power
Review of The Impact Of Hydrogen-Containing Fuels On Gas Turbine Hot-Section Materials
J. Eng. Gas Turbines Power
Effects of Lattice Orientation Angle On Tpms-Based Transpiration Cooling
J. Eng. Gas Turbines Power
Related Articles
Feasibility Study of an On-Board Natural Gas to Dimethyl Ether Reactor for Dimethyl Ether Preinjection and Enhanced Ignition
J. Eng. Gas Turbines Power (October,2005)
Reduction of Nitric Oxides and Soot by Premixed Fuel in Partial HCCI Engine
J. Eng. Gas Turbines Power (July,2006)
Effects of Fuel Injection Timing in the Combustion of Biofuels in a Diesel Engine at Partial Loads
J. Energy Resour. Technol (June,2011)
Comparisons of Diesel PCCI Combustion Simulations Using a Representative Interactive Flamelet Model and Direct Integration of CFD With Detailed Chemistry
J. Eng. Gas Turbines Power (January,2007)
Related Proceedings Papers
Related Chapters
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Determination of the Effects of Safflower Biodiesel and Its Blends with Diesel Fuel on Engine Performance and Emissions in a Single Cylinder Diesel Engine
International Conference on Software Technology and Engineering, 3rd (ICSTE 2011)
Lay-Up and Start-Up Practices
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration