In a large capacity tangentially fired boiler, the final reheater tubing sustained abnormal oxidation and localized excessive metal wastage in a short time of the unit operation. The root causes of the problem are identified by test data analysis. The test data indicated that the reheater tubing metal temperatures in the affected areas exceeded the recommended limit of the metal oxidation temperature due to higher than expected local gas temperatures and velocities. A soot-blower facing the overheated portion of the reheater leading tubes accelerated the process of metal wastage by periodically removing the oxide layer. The configuration of the boiler internals upstream of the reheater section is found to be the main cause of the localized overheating. Side-to-side gas flow/temperature stratification due to tangential firing contributed to a lesser degree to the problem. The results and conclusions presented in this paper should be a beneficial guide to the designer of large capacity boilers.

1.
Davies
,
M. H.
,
Simnad
,
M. T.
, and
Birchenall
,
C. E.
, 1951, “
On the Mechanism and Kinetics of the Scaling of Iron
,”
J. Met.
0148-6608,
3
, pp.
889
896
.
2.
French
,
D. N.
, 1982,
Metallurgical Failures in Fossil Fired Boilers
,
Wiley-Interscience
,
New York
, p.
153
.
3.
Llinares
,
V.
, and
Schmidt
,
S.
, 1993,
Peak Temperature Reduction in Superheater and Reheater Assemblies: Approaches and Solutions
,
ABB C-E Services, Inc.
, Windsor, CT., Technical paper No. TIS 8599.
4.
French
,
D. N.
, 1982,
Metallurgical Failures in Fossil Fired Boilers
,
Wiley-Interscience
,
New York
, p.
263
.
5.
Dooley
,
R. B.
, and
McNaughton
,
W. P.
, 1996,
Boiler Tube Failures: Theory and Practice, Volume 1: Boiler Tube Fundamentals
,
Electric Power Research Institute
,
Palo Alto, CA
, p.
215
.
6.
Armitt
,
J. R.
,
Holmes
,
M. I.
,
Manning
,
D. B.
, and
Metcalfe
,
E.
, 1978, “
The Spalling of Steam-Grown Oxide From Superheater and Reheater Tube Steels
,” Technical Planning Study 76-655,
Electric Power Research Institute
, Palo Alto, CA, Final Report No. FP-686.
7.
Rehn
,
I. M.
,
Apblett
,
W. R.
, Jr.
, and
Stringer
,
J.
, 1981, “
Controlling Steam-Side Oxide Exfoliation in Utility Boiler Superheaters and Reheaters
,”
Materials Performance
, Vol.
20
, pp.
27
31
.
8.
French
,
D. N.
, 1982,
Metallurgical Failures in Fossil Fired Boilers
,
Wiley-Interscience
,
New York
, p.
249
.
You do not currently have access to this content.