Abstract

Carbon disulfide is the solvent of choice for eluting adsorption packages prior to analysis by GC/FID. In laboratories which utilize mass selective detectors instead of flame ionization detectors, diethyl ether, a much friendlier solvent, can be used in place of the CS2. No loss of sensitivity occurs, and there is a salutary impact on bench workers' health as well as on the aroma of the fire debris laboratory.

References

1.
Jennings
W G
,
Nusten
H E
.
Gas chromatographic analysis of dilute aqueous systems
.
Anal Chem
1967
;
39
:
4
-
521
.
2.
Otterson
E J
,
Guy
C U
.
A method of atmospheric solvent vapor sampling on activated charcoal in connection with gas chromatography
. Transaction on the
26th annual meeting of the American Conference of Governmental Industrial Hygienists
,
Philadelphia
.
American Conference of Governmental Industrial Hygienists
;
1964
:37.
3.
Baldwin
R E
.
Adsorption-elution technique for concentration of hydrocarbon vapors
.
Arson Anal Newsletter
1977
;
1
:
6
-
9
.
4.
Chrostowski
J E
,
Holmes
R N
.
Collection and determination of accelerant vapors from arson debris
.
Arson Anal Newsletter
1979
;
3
:
5
-
3
.
5.
Melcher
R G
,
Langner
R R
,
Kagel
R O
.
Criteria for the evaluation of methods for the collection of organic pollutants in air using solid sorbents
.
AIHA
1978
;
39
:349.
This content is only available via PDF.