Abstract

This paper describes a study designed to investigate the effects of light sources used to enhance fingermarks on the subsequent polymerase chain reaction (PCR)-short tandem repeat (STR) analysis of bloodstains. Dried bloodstains on glass were exposed for up to 30 min to five different light sources: Argon ion laser, Polilight UV, Polilight green, Superlite, and shortwave UV. The bloodstains were subsequently analyzed using a quadruplex PCR system. It was found that treating the bloodstains with four of the five light sources had no appreciable effect on the results obtained from subsequent PCR analysis. However, exposure of the bloodstains to shortwave UV light for more than 30 s precluded the acquisition of results from PCR testing. Therefore, under casework conditions, it would be preferable to avoid exposing bloodstains, on which PCR typing is to be performed, to shortwave UV.

References

1.
Kimpton
C P
,
Fisher
D
,
Watson
S
,
Adams
M
,
Urquhart
A
,
Lygo
J
, et al
Automated DNA profiling employing multiplex amplification of short tandem repeat loci
.
PCR Methods Appl
1993
;
3
:
13
-
22
.
2.
Kimpton
C P
,
Walton
A
,
Gill
P
.
A further tetranucleotide polymorphism in the vWF gene
.
Hum Mol Genet
1992
;
1
:287.
3.
Polymeropolous
M H
,
Xiao
H
,
Rath
D S
,
Merril
C R
.
Tetranucleotide repeat polymorphism at the human tyrosine hydrolase gene
.
Nucleic Acids Res
1991
;
19
:3753.
4.
Polymeropoulos
M H
,
Rath
D S
,
Xiao
H
,
Merril
C R
.
Tetranucleotide repeat polymorphism at the human coagulation factor XIIIA subunit gene
.
Nucleic Acids Res
1991
;
19
:4036.
5.
Polymeropoulos
M H
,
Rath
D S
,
Xiao
H
,
Merril
C R
.
Tetranucleotide repeat polymorphism at the human c-fes/fps proto-oncogene
.
Nucleic Acids Res
1991
;
19
:4018.
6.
Urquhart
A
,
Kimpton
C P
,
Downs
T J
,
Gill
P
.
Variation in short tandem repeat sequences—a survey of twelve microsatellite loci for use as forensic identification markers
.
Int J Leg Med
1994
;
107
:
13
-
20
.
7.
Lygo
J E
,
Johnson
P E
,
Holdaway
D J
,
Woodroffe
S
,
Whitaker
J P
,
Clayton
T M
, et al
The validation of short tandem repeat loci for use in forensic casework
.
Int J Leg Med
1994
;
107
:
77
-
89
.
8.
Andersen
J F
,
Greenhalgh
M J
,
Butler
H R
,
Kilpatrick
S R
,
Piercy
R C
,
Way
K A
, et al
Further validation of a multiplex STR system for use in routine forensic identity testing
.
Forensic Sci Int
1996
;
78
:
47
-
64
.
9.
Walsh
P S
,
Metzgar
D A
,
Higuchi
R
.
Chelex® 100 as a medium for the simple extraction of DNA for PCR-based typing from forensic material
.
Biotechniques
1991
;
1
:
91
-
8
.
10.
Walsh
P S
,
Varario
,
Reynolds
R
.
A rapid chemiluminescent method for quantitation of human DNA
.
Nucleic Acids Res
1992
;
20
:
5061
-
5
.
11.
Elder
J K
,
Southern
E
.
Computer-aided analysis of one-dimensional restriction length fragment gels
. In:
Bishop
M J
,
Rawling
C K
, editors.
Nucleic Acid and Protein Sequence Analysis
.
Oxford
,
IRL Press
,
1987
;
165
-
72
.
12.
Lee
H C
,
Gaensslen
R E
,
Pagliaro
E M
,
Guman
M B
,
Keith
T P
,
Phipps
P
.
The effect of presumptive test, latent fingerprint and some other reagents and materials on subsequent serological identification, genetic marker and DNA testing in bloodstains
.
Forensic Ident
1989
;
39
(
6
):
339
-
58
.
13.
Shipp
E
,
Roelofs
R
,
Togneri
E
,
Wright
R
,
Atkinson
D
,
Henry
B
.
Effects of argon laser, alternate source light and cyanoacrylate fuming on DNA typing of human bloodstains
.
Forensic Sci
1993
;
38
(
1
):
184
-
91
.
This content is only available via PDF.
You do not currently have access to this content.