Measurements of the pressure drops for water flowing in small diameter tubes having U-type wavy configuration are presented. The inner diameters of the test copper tubes D are 3.43, 5.07, and 8.29 mm, whereas the curvature ratios 2R/D and spacer length L/D span from 3.75 to 7.87 and 1.93 to 7.0, respectively. The test range of the Reynolds number for water is about 200<Re<18000. The measured pressure loss in U-type wavy tube includes the loss in U-bends and the loss caused by the distorted flow in the downstream straight tube. Thus, an equivalent friction factor, fB, is then defined. For both laminar and turbulent flow the bend friction factor increases with the decrease of dimensionless curvature ratio and spacer length. The test results indicate that the recent reported correlations by Popiel and Wojkowiak (2000) and Wojkowiak (2000) do not accurately predict the data. A simple friction factor equation is developed based on the experimental data with characterizing parameters like curvature ratio and spacer length, new Dean number, and the Reynolds number. A good agreement with a mean standard deviation of 5.6% is observed between the proposed correlation and the existing data, which includes the test results of this study and those from Popiel and Wojtkowiak (2000).

1.
Dean
,
W. R.
,
1927
, “
Note on the Motion of Fluid in a Curved Pipe
,”
Philos. Mag.
,
4
, pp.
208
695
.
2.
Barua
,
S. N.
,
1963
, “
On Secondary Flow in Stationary Curved Pipes
,”
Q. J. Mech. Appl. Math.
,
16
, pp.
61
70
.
3.
Cheng
,
K. C.
, and
Yuen
,
F. P.
,
1987
, “
Flow Visualization Studies on Secondary Flow Patterns in Straight Tubes Downstream of a 180-deg Bend and in Isothermally Heated Horizontal Tubes
,”
ASME J. Heat Transfer
,
109
, pp.
49
61
.
4.
Ito
,
H.
,
1960
, “
Pressure Losses in Smooth Pipe Bends
,”
ASME J. Basic Eng.
,
82
, pp.
131
143
.
5.
Manlapaz
,
R. L.
, and
Churchill
,
S. W.
,
1980
, “
Fully Developed Laminar Flow in a Helical Coiled Tube of Finite Pitch
,”
Chem. Commun. (Cambridge)
,
7
, pp.
57
58
.
6.
Cho
,
K.
, and
Tae
,
S. J.
,
2000
, “
Evaporation Heat Transfer for R-22 and R-407 Refrigerant-Oil Mixture in a Microfin Tube With a U-Bend
,”
Int. J. Refrig.
,
23
, pp.
219
231
.
7.
Cho
,
K.
, and
Tae
,
S. J.
,
2001
, “
Condensation Heat Transfer for R-22 and R-407 Refrigerant-Oil Mixtures in a Microfin Tube With a U-Bend
,”
Int. J. Heat Mass Transfer
,
44
, pp.
2043
2051
.
8.
Popiel
,
C. O.
, and
Wojtkowiak
,
J.
,
2000
, “
Friction Factor in U-Type Undulated Pipe
,”
ASME J. Fluids Eng.
,
122
, pp.
260
263
.
9.
Wojtkowiak
,
J.
, and
Popiel
,
C. O.
,
2000
, “
Effect of Cooling on Pressure Losses in U-Type Wavy Pipe Flow
,”
Int. Commun. Heat Mass Transfer
,
27
, pp.
169
177
.
10.
Chen
,
I. Y.
,
Yang
,
K. S.
, and
Wang
,
C. C.
,
2001
, “
Two-Phase Frictional Pressure Drop of Air-Water in Small Horizontal Tubes
,”
J. Thermophys. Heat Transfer
,
15
(
4
), pp.
409
415
.
11.
Geary
,
D. F.
,
1975
, “
Return Bend Pressure Drop in Refrigerating Systems
,”
ASHRAE Trans.
,
81
(
1
), pp.
250
265
.
12.
Moffat
,
R. J.
,
1988
, “
Describing the Uncertainties in Experimental Results
,”
Exp. Therm. Fluid Sci.
,
1
, pp.
3
17
.
13.
Mishra
,
P.
, and
Gupta
,
S. H.
,
1979
, “
Momentum Transfer in Curved Pipes. 1. Newtonian Fluids
,”
Ind. Eng. Chem. Process Des. Dev.
,
18
(
1
), pp.
130
137
.
14.
Popiel, C. O., private communication with I. Y. Chen and C. C. Wang.
15.
Chen
,
I. Y.
,
Yang
,
Y. W.
, and
Wang
,
C. C.
,
2002
, “
Influence of Horizontal Return Bend on the Two-Phase Flow Pattern in a 6.9-mm Diameter Tube
,”
Can. J. Chem. Eng.
,
80
(
3
), pp.
478
484
.
You do not currently have access to this content.