This paper presents a new model for the study of air entrainment on the extreme pressure surges in pumping systems. For the present fluid system considered with a weir discharge chamber, numerical investigations showed that, with the proposed model of the air entrainment, reasonable predictions of transient pressures with proper phasing and attenuation of pressure peaks can be obtained. The results obtained are consistent with observations from field measurements made when the pumps were operating at low pump cutout levels where air entrainment due to attached surface vortex and falling jets from the inflow near the pump intake were present. Further studies were also made on the design characteristics of the weir discharge chamber on the extreme pressure transients for the unsteady flow in the pipeline system with various degrees of air entrainment.
Skip Nav Destination
e-mail: mpeleets@nus.edu.sg
Article navigation
December 2002
Additional Technical Papers
Air Entrainment Effects on the Pressure Transients of Pumping Systems With Weir Discharge Chamber
T. S. Lee, Associate Professor,,
e-mail: mpeleets@nus.edu.sg
T. S. Lee, Associate Professor,
Mechanical Engineering Department, National University of Singapore, Singapore 119260, Singapore
Search for other works by this author on:
K. L. Ngoh
K. L. Ngoh
Mechanical Engineering Department, National University of Singapore, Singapore 119260, Singapore
Search for other works by this author on:
T. S. Lee, Associate Professor,
Mechanical Engineering Department, National University of Singapore, Singapore 119260, Singapore
e-mail: mpeleets@nus.edu.sg
K. L. Ngoh
Mechanical Engineering Department, National University of Singapore, Singapore 119260, Singapore
Contributed by the Fluids Engineering Division for publication in the JOURNAL OF FLUIDS ENGINEERING. Manuscript received by the Fluids Engineering Division May 5, 2000, revised manuscript received May 3, 2002. Associate Editor: B. Schiavello.
J. Fluids Eng. Dec 2002, 124(4): 1034-1043 (10 pages)
Published Online: December 4, 2002
Article history
Received:
May 5, 2000
Revised:
May 3, 2002
Online:
December 4, 2002
Citation
Lee, T. S., and Ngoh, K. L. (December 4, 2002). "Air Entrainment Effects on the Pressure Transients of Pumping Systems With Weir Discharge Chamber ." ASME. J. Fluids Eng. December 2002; 124(4): 1034–1043. https://doi.org/10.1115/1.1514204
Download citation file:
Get Email Alerts
Cited By
Related Articles
Effects of Air Entrainment on the Ability of Air Vessels in the Pressure Surge Suppressions
J. Fluids Eng (September,2000)
Numerical Simulation of the Transient Flow in a Centrifugal Pump During Starting Period
J. Fluids Eng (August,2010)
CFD Calculation of a Mixed Flow Pump Characteristic From Shutoff to Maximum Flow
J. Fluids Eng (September,2002)
Fundamental Analysis on Rotor-Stator Interaction in a Diffuser Pump by Vortex Method
J. Fluids Eng (December,2001)
Related Chapters
Dynamic Behavior of Pumping Systems
Pipeline Pumping and Compression Systems: A Practical Approach
Internal and Near Nozzle Flow Simulations of Gasoline Multi-Hole Injector (ECN Spray G) with Transient Needle Motion
Proceedings of the 10th International Symposium on Cavitation (CAV2018)
Cavitating Structures at Inception in Turbulent Shear Flow
Proceedings of the 10th International Symposium on Cavitation (CAV2018)