The increasing demand for smaller more compact electronic systems as well as the need to handle higher levels of power dissipation has lead to an increase in necessity for more innovative cooling designs. In recent years, computational fluid dynamics (CFD) software has been used extensively in the design of thermal control systems for electronics. In many cases, there remains a need for experimental evaluation of cooling systems in order to validate the results of the CFD simulations. The present work investigates several variations of a liquid cooled base plate channel design for an array of generic power amplifier units. Several different channel insert configurations are investigated as miniheat exchangers using both copper fins and graphite foam. Experiments were conducted measuring the chip temperatures as well as the inlet liquid temperature. CFD simulations were also conducted to guide the experimental program. Effective heat transfer coefficients were also reverse-engineered using CFD software and the experimental results.
Skip Nav Destination
e-mail: zwilliams@mil-tec.com
Article navigation
December 2007
Research Papers
Thermal Management of a High Packing Density Array of Power Amplifiers Using Liquid Cooling
Z. A. Williams,
e-mail: zwilliams@mil-tec.com
Z. A. Williams
Engineer
Mem. ASME
Miltec Research and Technology
, 9 Industrial Park, Oxford, MS 38655
Search for other works by this author on:
J. A. Roux
J. A. Roux
Faculty
Mem. ASME
Mechanical Engineering,
University of Mississippi
, MS 38677
Search for other works by this author on:
Z. A. Williams
Engineer
Mem. ASME
Miltec Research and Technology
, 9 Industrial Park, Oxford, MS 38655e-mail: zwilliams@mil-tec.com
J. A. Roux
Faculty
Mem. ASME
Mechanical Engineering,
University of Mississippi
, MS 38677J. Electron. Packag. Dec 2007, 129(4): 488-495 (8 pages)
Published Online: April 19, 2007
Article history
Received:
January 18, 2007
Revised:
April 19, 2007
Citation
Williams, Z. A., and Roux, J. A. (April 19, 2007). "Thermal Management of a High Packing Density Array of Power Amplifiers Using Liquid Cooling." ASME. J. Electron. Packag. December 2007; 129(4): 488–495. https://doi.org/10.1115/1.2804100
Download citation file:
Get Email Alerts
Cited By
Impact of Encapsulated Phase Change Material Additives for Improved Thermal Performance of Silicone Gel Insulation
J. Electron. Packag (December 2024)
Special Issue on InterPACK2023
J. Electron. Packag
Related Articles
Graphite Foam Thermal Management of a High Packing Density Array of Power Amplifiers
J. Electron. Packag (December,2006)
Performance of Graphite Foam Evaporator for Use in Thermal Management
J. Electron. Packag (June,2005)
Downhole Electronics Cooling Using a Thermoelectric Device and Heat Exchanger Arrangement
J. Electron. Packag (December,2011)
Effect of Surface Orientation on Nucleate Boiling of FC-72 on Porous Graphite
J. Heat Transfer (November,2006)
Related Proceedings Papers
Related Chapters
Natural Gas Transmission
Pipeline Design & Construction: A Practical Approach, Third Edition
Generation of Design Data – Finite Volume Analysis
Compact Heat Exchangers: Analysis, Design and Optimization using FEM and CFD Approach
Iowa State University Research Reactor
Decommissioning Handbook