Skip Nav Destination
Issues
May 2011
ISSN 0148-0731
EISSN 1528-8951
In this Issue
Research Papers
Comparison of LES of Steady Transitional Flow in an Idealized Stenosed Axisymmetric Artery Model With a RANS Transitional Model
J Biomech Eng. May 2011, 133(5): 051001.
doi: https://doi.org/10.1115/1.4003782
A Microstructurally Driven Model for Pulmonary Artery Tissue
Philip H. Kao, Steven R. Lammers, Lian Tian, Kendall Hunter, Kurt R. Stenmark, Robin Shandas, H. Jerry Qi
J Biomech Eng. May 2011, 133(5): 051002.
doi: https://doi.org/10.1115/1.4002698
Topics:
Biological tissues
,
Deformation
,
Fibers
,
Stress
,
Pulmonary artery
,
Modeling
,
Tensors
Validation of a New Method for Finding the Rotational Axes of the Knee Using Both Marker-Based Roentgen Stereophotogrammetric Analysis and 3D Video-Based Motion Analysis for Kinematic Measurements
J Biomech Eng. May 2011, 133(5): 051003.
doi: https://doi.org/10.1115/1.4003437
Topics:
Errors
,
Kinematics
,
Knee
,
Rotation
,
Simulation
,
Sensitivity analysis
Estimation of In Vivo ACL Force Changes in Response to Increased Weightbearing
J Biomech Eng. May 2011, 133(5): 051004.
doi: https://doi.org/10.1115/1.4003780
Topics:
Anterior cruciate ligament
,
Elongation
,
Weight (Mass)
A Robotic Cadaveric Flatfoot Analysis of Stance Phase
J Biomech Eng. May 2011, 133(5): 051005.
doi: https://doi.org/10.1115/1.4003869
Evaluating the Bending Response of Two Osseointegrated Transfemoral Implant Systems Using 3D Digital Image Correlation
J Biomech Eng. May 2011, 133(5): 051006.
doi: https://doi.org/10.1115/1.4003871
Topics:
Artificial limbs
,
Deformation
,
Failure
,
Manufacturing
,
Prostheses
,
Stress
,
Torque
,
Design
,
Data collection
,
Geometry
A Mixed Boundary Representation to Simulate the Displacement of a Biofluid by a Biomaterial in Porous Media
J Biomech Eng. May 2011, 133(5): 051007.
doi: https://doi.org/10.1115/1.4003735
Topics:
Biomaterials
,
Bone
,
Cements (Adhesives)
,
Displacement
,
Flow (Dynamics)
,
Fluids
,
Permeability
,
Porosity
,
Porous materials
,
Rheology
Characterizing Heterogeneous Properties of Cerebral Aneurysms With Unknown Stress-Free Geometry: A Precursor to In Vivo Identification
J Biomech Eng. May 2011, 133(5): 051008.
doi: https://doi.org/10.1115/1.4003872
Topics:
Aneurysms
,
Biological tissues
,
Geometry
,
Stress
,
Deformation
,
Finite element analysis
,
Elasticity
Differential Passive and Active Biaxial Mechanical Behaviors of Muscular and Elastic Arteries: Basilar Versus Common Carotid
J Biomech Eng. May 2011, 133(5): 051009.
doi: https://doi.org/10.1115/1.4003873
Topics:
Biomechanics
,
Carotid arteries
,
Constitutive equations
,
Fibers
,
Muscle
,
Stress
,
Vessels
,
Testing
,
Diseases
,
Pressure
Technical Briefs
Technical Issues in Using Robots to Reproduce Joint Specific Gait
J. M. Rosvold, S. P. Darcy, R. C. Peterson, Y. Achari, D. T. Corr, L. L. Marchuk, C. B. Frank, N. G. Shrive, Joshua M. Rosvold, Shon P. Darcy, Robert C. Peterson, Yamini Achari, David T. Corr, Linda L. Marchuk, Cyril B. Frank, Nigel G. Shrive
J Biomech Eng. May 2011, 133(5): 054501.
doi: https://doi.org/10.1115/1.4003665
Topics:
Robots
,
Stress
,
Stiffness
,
Kinematics
Email alerts
RSS Feeds
Simulating the Growth of TATA-Box Binding Protein-Associated Factor 15 Inclusions in Neuron Soma
J Biomech Eng (December 2024)
Evaluation of an Inverse Method for Quantifying Spatially Variable Mechanics
J Biomech Eng (December 2024)
Effect of Structure and Wearing Modes on the Protective Performance of Industrial Safety Helmet
J Biomech Eng (December 2024)
Sex-Based Differences and Asymmetry in Hip Kinematics During Unilateral Extension From Deep Hip Flexion
J Biomech Eng (December 2024)