Effects of cyclic stress on the mechanical properties of collagen fascicles were studied by in vitro tissue culture experiments. Collagen fascicles (approximately 300 μm in diameter) obtained from the rabbit patellar tendon were applied cyclic load at 4 Hz for one hour per day during culture period for one or two weeks, and then their mechanical properties were determined using a micro-tensile tester. There was a statistically significant correlation between tensile strength and applied peak stress in the range of 0 to 5 MPa, and the relation was expressed by a quadratic function. The maximum strength (19.4 MPa) was obtained at the applied peak stress of 1.8 MPa. The tensile strength of fascicles were within a range of control values, if they were cultured under peak stresses between 1.1 and 2.6 MPa. Similar results were also observed in the tangent modulus, which was maintained at control level under applied peak stresses between 0.9 and 2.8 MPa. The stress of 0.9 to 1.1 MPa is equivalent to approximately 40% of the in vivo peak stress which is developed in the intact rabbit patellar tendon by running, whereas that of 2.6 to 2.8 MPa corresponds to approximately 120% of the in vivo peak stress. Therefore, the fascicles cultured under applied peak stresses of lower than 40% and higher than 120% of the in vivo peak stress do not keep the original strength and modulus. These results indicate that the mechanical properties of cultured collagen fascicles strongly depend upon the magnitude of the stress applied during culture, which are similar to our previous results observed in stress-shielded and overstressed patellar tendons in vivo.
Skip Nav Destination
Article navigation
December 2003
Technical Papers
Effects of Cyclic Stress on the Mechanical Properties of Cultured Collagen Fascicles from the Rabbit Patellar Tendon
Ei Yamamoto,
Ei Yamamoto
Biomechanics Laboratory, Department of Mechanical Engineering and Biomimetics, School of Biology-Oriented Science and Technology, Kinki University, Naga, Wakayama 649-6493, Japan
Search for other works by this author on:
Susumu Tokura,
Susumu Tokura
Ishikawajima-Harima Heavy Industry, Yokohama, Kanagawa 235-8501, Japan
Search for other works by this author on:
Kozaburo Hayashi
Kozaburo Hayashi
Biomechanics Laboratory, Department of Mechanical Science and Bioengineering, Graduate School of Engineering Science, Osaka University, Toyonaka, Osaka 560-8531, Japan
Search for other works by this author on:
Ei Yamamoto
Biomechanics Laboratory, Department of Mechanical Engineering and Biomimetics, School of Biology-Oriented Science and Technology, Kinki University, Naga, Wakayama 649-6493, Japan
Susumu Tokura
Ishikawajima-Harima Heavy Industry, Yokohama, Kanagawa 235-8501, Japan
Kozaburo Hayashi
Biomechanics Laboratory, Department of Mechanical Science and Bioengineering, Graduate School of Engineering Science, Osaka University, Toyonaka, Osaka 560-8531, Japan
Contributed by the Bioengineering Division for publication in the JOURNAL OF BIOMECHANICAL ENGINEERING. Manuscript received by the Bioengineering Division February 15, 2002; revision received July 7, 2003. Associate Editor: L. J. Soslowsky
J Biomech Eng. Dec 2003, 125(6): 893-901 (9 pages)
Published Online: January 9, 2004
Article history
Received:
February 15, 2002
Revised:
July 7, 2003
Online:
January 9, 2004
Citation
Yamamoto, E., Tokura, S., and Hayashi, K. (January 9, 2004). "Effects of Cyclic Stress on the Mechanical Properties of Cultured Collagen Fascicles from the Rabbit Patellar Tendon ." ASME. J Biomech Eng. December 2003; 125(6): 893–901. https://doi.org/10.1115/1.1634286
Download citation file:
Get Email Alerts
Estimation of Joint Kinetics During Manual Material Handling Using Inertial Motion Capture: A Follow-Up Study
J Biomech Eng (February 2025)
Effect of Compressive Strain Rates on Viscoelasticity and Water Content in Intact Porcine Stomach Wall Tissues
J Biomech Eng (February 2025)
Eyelid Motion Tracking During Blinking Using High-Speed Imaging and Digital Image Correlation
J Biomech Eng (January 2025)
Related Articles
Effects of the Frequency and Duration of Cyclic Stress on the Mechanical Properties of Cultured Collagen Fascicles From the Rabbit Patellar Tendon
J Biomech Eng (December,2005)
Effects of Static Stress on the Mechanical Properties of Cultured Collagen Fascicles From the Rabbit Patellar Tendon
J Biomech Eng (February,2002)
The Role of Flow-Independent Viscoelasticity in the Biphasic Tensile and Compressive Responses of Articular Cartilage
J Biomech Eng (October,2001)
Ageing Changes in the Tensile Properties of Tendons: Influence of Collagen Fibril Volume Fraction
J Biomech Eng (April,2008)
Related Proceedings Papers
Related Chapters
Introduction
Ultrasonic Methods for Measurement of Small Motion and Deformation of Biological Tissues for Assessment of Viscoelasticity
Synthesis and Characterization of Carboxymethyl Chitosan Based Hybrid Biopolymer Scaffold
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3
Acceptance Criteria
Design of Hazardous Mechanical Structures, Systems and Components for Extreme Loads