Reference coordinates based on the finite helical axis for flexion of the knee from 0 to 90 deg are proposed. Six degree-of-freedom tracking allows the use of such a helical axis as a kinematic landmark for knee motion representation. Data from five human subjects in vivo are presented as a path of finite helical axes for flexion of the knee from 20 to 80 deg. The finite helical axis rotates by an average of 11.4 deg, the centrode translates an average of 19.8 mm, and the total axial translation averages 0.1 mm during flexion from 20 to 80 deg. Error due to the transducer was measured on a fixed-pivot pendulum and found to be 1.0 deg and 1.9 mm rms for the helical axis orientation and position, respectively, and 0.1 mm for the axial translation. Reproducibility and soft tissue effects on the measurements were repeatable to 4.0 deg and 2.7 mm rms in orientation and position, respectively, and 0.1 mm for the axial translations. Soft tissue errors averaged 4.9 deg and 3.6 mmm in position and orientation, and 0.3 mm in the axial translations.
Skip Nav Destination
Article navigation
Research Papers
A Finite Helical Axis as a Landmark for Kinematic Reference of the Knee
R. A. Hart,
R. A. Hart
School of Medicine, University of California, San Diego, CA
Search for other works by this author on:
C. D. Mote, Jr.,
C. D. Mote, Jr.
Department of Mechanical Engineering, University of California, Berkeley, Berkeley, CA 94720
Search for other works by this author on:
H. B. Skinner
H. B. Skinner
University of California, San Fransisco, CA
Search for other works by this author on:
R. A. Hart
School of Medicine, University of California, San Diego, CA
C. D. Mote, Jr.
Department of Mechanical Engineering, University of California, Berkeley, Berkeley, CA 94720
H. B. Skinner
University of California, San Fransisco, CA
J Biomech Eng. May 1991, 113(2): 215-222 (8 pages)
Published Online: May 1, 1991
Article history
Received:
January 12, 1989
Revised:
December 1, 1990
Online:
March 17, 2008
Citation
Hart, R. A., Mote, C. D., Jr., and Skinner, H. B. (May 1, 1991). "A Finite Helical Axis as a Landmark for Kinematic Reference of the Knee." ASME. J Biomech Eng. May 1991; 113(2): 215–222. https://doi.org/10.1115/1.2891237
Download citation file:
Get Email Alerts
Related Articles
Knee Joint Secondary Motion Accuracy Improved by Quaternion-Based Optimizer With Bony Landmark Constraints
J Biomech Eng (December,2010)
A Six-Degree-of-Freedom Acoustic Transducer for Rotation and Translation Measurements Across the Knee
J Biomech Eng (November,1990)
Dynamic Models for Sideways Falls From Standing Height
J Biomech Eng (August,1995)
Related Proceedings Papers
Related Chapters
Introduction and Scope
High Frequency Piezo-Composite Micromachined Ultrasound Transducer Array Technology for Biomedical Imaging
Infinitesimal Mechanics of the PKMs
Mechanics of Accuracy in Engineering Design of Machines and Robots Volume I: Nominal Functioning and Geometric Accuracy
Implementation of an Internet-Based Tele-Operation for the Control of an Inverted Pendulum
Intelligent Engineering Systems through Artificial Neural Networks